Precision Digital PD6001 ProVu Feet & Inches Level Meter

Last Updated: 28/05/2020
Precision Digital Logo

Precision Digital PD6001-6R4

$694

Usually ships in 1 to 2 weeks

Part Number: PD6001-6R4 Categories: , , Tags: ,
  • Free Shipping
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm or Email sales@celectric.com.my

    FREE Domestic AND SEA Shipping!

    Most orders RM500/USD120 or more ship SEA for FREE!

    • Delivery within the Southeast Asia only.
    • Hazardous items excluded.
    • Extremely heavy or bulky items excluded.
    • Distributors, Resellers and OEMs excluded.
    • Contact us for shipping charge for orders < RM500/USD120
    close-link
  • Free Technical Support
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm

    Setup, Configuration and Technical Support of our Products are FREE.

    We help to check your faulty Instruments too, fill in the form here

    Free phone and email tech support continues as long as you own the product. Click here for contact information.

    close-link
  • SKU: PD6001-6R4 
    Product Type: 1/8 DIN Feet & Inches Level Digital Panel Meter 
    Input: Current (4-20 mA), Voltage (0-10 V) 
    Output Options: 4 Relays 
    Power: 85-265 VAC, 90-265 VDC 
    Approvals: CE, UL/C-UL 
    Transmitter Power: 24 VDC @ 200 mA 
    Display Category: LED, Dual Line, Feet & Inches 
    Display: 0.6″ High, Dual Line, 6 Digits, F & I, Red LED 
    Warranty: 3 years 
    Product Series: ProVu 
    Product Family: PD6001 
    Product category: Digital Panel Meters 
    Product Application: Level, Process, Pump Control

    Wiring Diagram:

    The PD6001 is a member of the ProVu® series of 1/8 DIN digital panel meters specifically designed to display level in feet and inches, instead of the usual decimal format. The PD6001 accepts a process current (4-20 mA) or process voltage (0-5V, 1-5V, etc.) signal and displays that signal on a dual line display with convenient feet and inches designations on the upper line. The upper display can even read fractions of an inch in 8ths or 16ths. The lower line can be used to indicate a tag or to display the input in another scale, such as volume in gallons or liters. Like all ProVu meters, the PD6001 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output and Modbus® serial communications. The PD6001 includes a 24 VDC power supply to drive the transmitter and can be programmed via the front panel pushbuttons or free MeterView® Pro software.

    General

    Display: Upper feet & inches display: 0.60″ (15 mm) high with feet & inches designations. Lower display: 0.46″ (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs.
    Feet & Inches Display Range: 0″ 00″ 0/16″ to 99″ 11″ 15/16″
    Display Intensity: Eight intensity levels
    Display Update Rate: 5/second (200 ms)
    Overrange: Display flashes 999999
    Underrange: Display flashes -99999
    Display Assignment: The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max & min, set points, units (lower display only), or Modbus input.
    Front Panel: NEMA 4X, IP65
    Programming Methods: Four front panel buttons, digital inputs, PC and MeterView Pro software, Modbus registers
    F4 Digital Input Contacts: 3.3 VDC on contact. Connect normally open contacts across F4 to COM.
    F4 Digital Input Logic Levels: Logic High: 3 to 5 VDC
    Logic Low: 0 to 1.25 VDC
    Noise filter: Programmable from 2 to 199 (0 will disable filter)
    Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
    Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months.
    Max/Min Display: Max / min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
    Password: Three programmable passwords restrict modification of programmed settings.
    Non-Volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
    Input Power Options: 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max or 12-24 VDC ± 10%, 15 W max. Powered over USB for configuration only.
    Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
    Isolated Transmitter Power Supply: Terminals P+ & P-: 24 VDC ± 10%. 12-24 VDC powered models selectable for 24, 10, or 5 VDC supply (internal P+/P- switch). 85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply.
    Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
    Isolation: 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
    Overvoltage Category: Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
    Environmental: Operating temperature range: -40 to 65°C
    Storage temperature range: -40 to 85°C
    Relative humidity: 0 to 90% non-condensing
    Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
    Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
    Mounting: 1/8 DIN panel cutout required: 3.622″ x 1.772″ (92 mm x 45 mm). Two panel mounting bracket assemblies are provided.
    Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
    Dimensions: 4.68″ x 2.45″ x 5.64″ (119 mm x 62 mm x 143 mm) (W x H x D)
    Weight: 9.5 oz (269 g)
    UL File Number: UL & C-UL Listed. E160849; 508 Industrial Control Equipment.
    Warranty: 3 years parts & labor
    USB Connection: Compatibility: USB 2.0 Standard, Compliant
       Connector Type: Micro-B receptacle
       Cable: USB A Male to Micro-B Cable
       Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit,
       Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
       Power: USB Port

    Process Input

    Inputs: Field selectable: 0-20, 4-20 mA, ±10 VDC (0-5, 1-5, 0-10 V), Modbus PV (Slave)
    Accuracy: ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-100% of calibrated span
    Temperature Drift: 0.005% of calibrated span/°C max from 0 to 65°C ambient, 0.01% of calibrated span/°C max from -40 to 0°C ambient
    Signal Input Conditioning: Linear or round horizontal tank volume calculation.
    Multi-Point Linearization: 2 to 32 points for PV or PV1. 2 to 8 points for PV2 (Dual-Scale Level feature)
    Programmable Exponent: 1.0001 to 2.9999 
    Low-Flow Cutoff: 0-999999 (0 disables cutoff function)
    Decimal Point: Up to five decimal places or none: d.ddddd, dd.dddd, ddd.ddd, dddd.dd, ddddd.d, or dddddd.
    Calibration Range: 4-20 mA: minimum span input 1 & input 2: 0.15 mA. ±10 V: minimum span input 1 & 2: 0.10 V. An Error message will appear if input 1 and input 2 signals are too close together. 
    Input Impedance: Voltage ranges: greater than 1 MΩ. Current ranges: 50 – 100 Ω (depending on resettable fuse impedance).
    Input Overload: Current input protected by resettable fuse, 30 VDC max. Fuse resets automatically after fault is removed.
    HART Transparency: Analog input will not interfere with existing HART communications on the wired 4-20 mA signal

    Relays

    Rating: 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (≈ 50 watts) @ 125/250 VAC for inductive loads such as contactors, solenoids, etc.
    Noise Suppression: Noise suppression is recommended for each relay contact switching inductive loads.
    Deadband: 0-100% of span, user programmable
    High or Low Alarm: User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turned off).
    Relay Operation: Automatic (non-latching), latching (requires manual acknowledge), sampling (based on time), pump alternation control (2 to 8 relays), Off (disable unused relays and enable interlock feature, manual on/off control mode).

    Relay Reset:
     User selectable via front panel buttons or digital inputs.
    1. Automatic reset only (non-latching), when input passes the reset point.
    2. Automatic + manual reset at any time (non-latching).
    3. Manual reset only, at any time (latching).
    4. Manual reset only after alarm condition has cleared (latching).
    Note: Front panel button or digital input may be assigned to acknowledge relays programmed for manual reset.
    Time Delay: 0 to 999.9 seconds, on & off relay time delays. Programmable and independent for each relay.
    Fail-Safe Operation: Programmable and independent for each relay.
    Note: Relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state.

    Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter.

    Serial Communications

    Protocol: Modbus® RTU (Slave Only)

    Meter Address/Slave ID:
     1 – 247
    Baud Rate: 300 – 19,200 bps
    Transmit Time Delay: Programmable between 0 and 199 ms or transmitter always on for RS-422 communicationv
    Data: 8 bit (1 start bit, 1 or 2 stop bits)
    Parity: Even, odd, or none with 1 or 2 stop bits
    Byte-to-Byte Timeout: 0.01 – 2.54 seconds
    Turn Around Delay: Less than 2 ms (fixed)
    Note: Refer to the ProVu Modbus Register Tables for details

    Isolated 4-20 mA Transmitter Output

    Output Source: Process variable (PV), max, min, set points 1-8, manual control setting, or Modbus input
    Scaling Range: 1.000 to 23.000 mA for any display range
    Calibration: Factory calibrated: 4.000 to 20.000 = 4-20 mA output
    Analog Output Programming: 23.000 mA maximum for all parameters:Overrange, underrange, max, min, and break
    Accuracy: ± 0.1% of span ± 0.004 mA
    Temperature Drift: 0.4 µA/°C max from 0 to 65°C ambient, 0.8 µA/°C max from -40 to 0°C ambient
    Note: Analog output drift is separate from input drift.
    Isolated Transmitter Power Supply: Terminals I+ & R: 24 VDC ± 10%. Isolated from the input at >500 V. May be used to power the 4-20 mA output or other devices. All models rated @ 40 mA max.

    Power supplyMinimumMaximum
    24 VDC10Ω700Ω
    35 VDC (external)100Ω1200Ω

    Digital I/O Expansion Module

    Channels: 4 digital inputs & 4 digital outputs per module
    System: Up to 2 modules for a total of 8 inputs & 8 outputs
    Digital Input Logic: High: 3 to 5 VDC
    Low: 0 to 1.25 VDC
    Digital Output Logic: High: 3.1 to 3.3 VDC
    Low: 0 to 0.4 VDC
    Source Current: 10 mA maximum
    Sink Current: 1.5 mA minimum
    +5 V Terminal: To be used as pull-up for digital inputs only

    4-Relay Expansion Module

    Relays: (4) Form A (SPST) rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (approx. 50 watts) @ 125/250 VAC for inductive loads

    Applications

    Signal Input Conditioning

    Non-linear input signals can be linearized with the ProVu’s simple to use round horizontal tank linearizer or the ProVu’s powerful general purpose linearizer.


    8-Point Linearizer for Volume

    Round Horizontal Tank Signal Input Conditioner

    Multi-Pump Alternation

    For pump control applications where 2 or more similar pumps are used to control the level of a tank or a well, it is desirable to have the pumps operate alternately; this prevents excessive wear and overheating of one pump over the lack of use of the others. The ProVu can accommodate up to 8 pumps. In the example below, a pair of relays have been set up to alternate every time an on/off pump cycle is completed. Another pair of relays is used for low and high alarms.

    Connections

    Mounting Dimensions

    ProVuDimensions


    Notes:

    1. Panel cutout required: 1.772″ x 3.622″ (45mm x 92mm)
    2. Panel thickness: 0.040 – 0.250″ (1.0mm – 6.4mm)
    3. Mounting brackets lock in place for easy mounting
    4. Clearance: Allow 6″ (152 mm) behind the panel

    MeterView® Pro Software

    MeterView® Pro software is designed for use with ProVu, ProtEX-MAX, or Helios Series meters and allows users to remotely program, monitor, and datalog using a PC. Remote programming allows for all available meter settings to be programmed through an easy, user-friendly interface. The data acquisition feature allows the user to gather readings from a meter at user-selected intervals and generate charts using common tools like Microsoft® Excel. A linearization setup function is also included. With this utility the user can configure up to 32 linearization points and upload them to the meter. All configuration data can be saved to a file for future use.
    This software is accessible via the onboard USB connection on all Helios large display meters, ProVu panel meters, and ProVu-based ProtEX-MAX explosion-proof meters produced since 6 September 2016 (firmware version 4.0 or higher). In order for meters produced prior to 6 September 2016 (firmware version 3.1 or lower) to establish digital communications with a PC, a serial communications adapter is required. For an RS-232 connection, use a PDA1232adapter.
    To determine the software version of a meter:

    1. Go to the Diagnostics menu () and press Enter button.
    2. Press Up arrow button and scroll to Information menu (Info).
    3. Press Enter to access the software number (), version (), and serial number () information. Write down the information as it is displayed. Continue pressing Enter until all the information is displayed.
    4. The meter returns to Run Mode after displaying all the settings.

    Click here for more information about MeterView Pro.
    Click here to watch an introductory video on MeterView Pro.

    Monitor and Datalog

    monitor and data logging
    monitor and data logging

    Setup

    Setup
    Setup

    Programming

    programming

    Relays

    Relays

    Data Sheet: LDS6001 Datasheets

    Instruction Manual: LIM6001_2 Instruction Manuals

    Quick Start Manual: 

    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm

    Setup, Configuration and Technical Support of our Products are FREE.

    We help to check your faulty Instruments too, fill in the form here

    Free phone and email tech support continues as long as you own the product. Click here for contact information.

    close-link
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm or Email sales@celectric.com.my

    FREE Domestic AND SEA Shipping!

    Most orders RM500/USD120 or more ship SEA for FREE!

    • Delivery within the Southeast Asia only.
    • Hazardous items excluded.
    • Extremely heavy or bulky items excluded.
    • Distributors, Resellers and OEMs excluded.
    • Contact us for shipping charge for orders < RM500/USD120
    close-link
    close-link

    Product of the week

    Loop Powered Indicator
    Loop Powered Flow Indicating Totalizer are in-stock now, and deliver immediately.
    Free delivery within Malaysia.
    Buy Here!
    close-link
    Scroll to Top
    ×