Precision Digital PD6081 ProVu Feet & Inches Modbus Scanner with Dual Analog Inputs

Last Updated: 23/02/2020
Precision Digital Logo

Precision Digital PD6081-7H4

$1,065

Usually ships in 1 to 2 weeks

Part Number: PD6081-7H4 Categories: , Tag:
  • Free Shipping
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm or Email sales@celectric.com.my

    FREE Domestic AND SEA Shipping!

    Most orders RM500/USD120 or more ship SEA for FREE!

    • Delivery within the Southeast Asia only.
    • Hazardous items excluded.
    • Extremely heavy or bulky items excluded.
    • Distributors, Resellers and OEMs excluded.
    • Contact us for shipping charge for orders < RM500/USD120
    close-link
  • Free Technical Support
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm

    Setup, Configuration and Technical Support of our Products are FREE.

    We help to check your faulty Instruments too, fill in the form here

    Free phone and email tech support continues as long as you own the product. Click here for contact information.

    close-link
  • Request a Quote
    close-link

    SKU: PD6081-7H4 
    Product Type: 1/8 DIN Feet & Inches Modbus RTU Scanner 
    Input: Current (4-20 mA), Dual Inputs, Multiple Inputs, Voltage (0-10 V), Modbus 
    Output Options: 4 Relays 
    Power: 12-24 VDC/VAC 
    Approvals: CE, UL/C-UL 
    Transmitter Power: 24 VDC @ 100 mA 
    Display Category: LED, Dual Line, Sunlight Readable, Feet & Inches 
    Display: SunBright, 0.6″, Dual Line, 6 Digits, F & I, Red LED 
    Warranty: 3 years 
    Product Series: ProVu 
    Product Family: PD6081 
    Product category: Digital Panel Meters, Modbus Scanner 
    Product Application: Level, Pressure, Process, Pump Control, Modbus

    Wiring Diagram:

    The ProVu® PD6081 Super Snooper feet & inches Modbus® scanner displays level information on a specially designed feet & inches display, instead of the usual decimal format. It is the ideal display for Modbus level or multivariable transmitters and is capable of scanning up to 16 Modbus process variables. Its unique feet & inches upper LED display can indicate up to 99 feet, 11 and 15/16 inches. The 6-digit lower display can indicate units, tags, or other variables such as volume, temperature, or density. The PD6081 also has dual analog inputs, for integrating traditional 4-20 mA or voltage inputs in the display scanning. The PD6081 can be setup as a Modbus master, slave, or snooper. Like all ProVu meters, the PD6081 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    General

    Input/Output: Modbus RTU over RS-485, Two analog inputs (4-20 mA, ±10 V)
    Display: Upper display: 0.60″ (15 mm) high. Lower display: 0.46″ (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs
    Display Intensity: Eight user selectable intensity levels
    Display Scan Rate: Master/Snooper: 1/second to once every 99.9 seconds. Slave: Dependent on master device (e.g., PLC)
    Overrange: Display flashes 999999
    Underrange: Display flashes -99999
    Display Assignment: The top display may be assigned to PV (process values), Ch C (math channel), PV & units, tag & PV, tag-PV-units, C & units, tag-C-unit, Setpoint 1-8, max/min PV, max/min C. The bottom display may be assigned to all of the above, tag, or off. The tag and units are displayed alternately for 2 sec when selected. Different tags & PVs may be selected to display on the top and bottom displays at the same time.
    Front Panel: NEMA 4X, IP65
    Programming Methods: Four front panel buttons, digital inputs, PC and MeterView Pro software, Modbus registers
    F4 Digital Input Contacts: 3.3 VDC on contact. Connect normally open contacts across F4 to COM.
    F4 Digital Input Logic Levels: Logic High: 3 to 5 VDC
    Noise filter: Programmable from 2 to 199 (0 will disable filter)
    Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
    Recalibration: All ranges are calibrated at the factory. Recalibration is recommended at least every 12 months.
    Max/Min Display: Max (Peak) / min (Valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled.
    Password: Three programmable passwords restrict modification of programmed settings.
    Non-Volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
    Power Options: 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max or 12-24 VDC ± 10%, 15 W max. Powered over USB for configuration only.
    Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
    Isolated Transmitter Power Supply: Terminals P+ & P-: 24 VDC ± 10%. 12-24 VDC powered models selectable for 24, 10, or 5 VDC supply (internal P+/P- switch). 85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply.
    Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
    Isolation: 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
    Overvoltage Category: Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
    Environmental:
       Operating temperature range: -40 to 65°C
       Storage temperature range: -40 to 85°C
       Relative humidity: 0 to 90% non-condensing
    Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
    Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
    Mounting: 1/8 DIN panel cutout required: 3.622″ x 1.772″ (92 mm x 45 mm). Two-panel mounting bracket assemblies are provided.
    Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
    Overall Dimensions: 4.68″ x 2.45″ x 5.64″ (119 mm x 62 mm x 143 mm) (W x H x D)
    Weight: 9.5 oz (269 g)
    UL File Number: UL & c-UL Listed. E160849; 508 Industrial Control Equipment.
    Warranty: 3 years parts & labor
    USB Connection: Compatibility: USB 2.0 Standard, Compliant
       Connector Type: Micro-B receptacle
       Cable: USB A Male to Micro-B Cable
       Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit,
       Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
       Power: USB Port

    Serial Communications

    Meter Address/Scanner ID: 1 – 247, 256-259 (for Volts and mA).
    Baud Rate: 300 – 19,200 bps
    Transmit Time Delay: Programmable between 0 and 199 ms
    Data: 8 bit (1 start bit, 1 or 2 stop bits)
    Parity: Even, odd, or none with 1 or 2 stop bits
    Byte-to-Byte Timeout: 0.01 – 2.54 seconds
    Turn Around Delay: Less than 2 ms (fixed)
    Operating Modes:
       MASTER: Processes data read from Modbus RTU slave devices. It polls up to 16 process variables from 1 to 16 slave devices. The Master is capable of scanning the selected PVs, scale the data, trigger relays, perform math operations, and drive the analog outputs.
       SNOOPER: Listens to the Modbus traffic and picks up a specific register or registers being polled by a master device from a specific slave device and processes the data being read. The Snooper mode handles the data the same way as the Master.
       SLAVE: Processes data sent to it from a Modbus RTU master device.
    PV Number: PV1–PV16 Enable or disable the process variables to be polled by the Master.
    Slave ID: Assign the slave ID or address (1-247, 256-259 for mA or volts inputs) containing the process variables to be displayed by the selected PV.
    Function Code: Select which Modbus function code (03, 04, or 65) to use in reading the slave device.
    Register Number: 5 digit: 30001-39999, 40001-49999, or 1-65,536
    6 digit: 300001-365536 or 400001-465536 (Function Code 65 N/A here) Specifies which register(s) to read in the slave device. Range is dependent on Function Code selection (65, 04, or 03) and digits selection (5 or 6).
    Data Type: Select the data format that the slave device uses. Select between Short integer (2 bytes), Long integer (4 bytes), or floating point (4 bytes), Signed or Unsigned (integer only) and byte order: 1234, 4321, 2143, or 3412 (big-endian vs. little-endian, or swapped).
    Poll Time: 1.0 to 99.9 sec. The time between read-commands (Master mode).
    Slave Response Timeout: 0.0 to 99.9 seconds: Time allowed for the slave to respond before the scanner generates a communication break condition. The master polls the slave three times before starting the response timeout timer. Slave/Snooper mode: Time the scanner will wait for new data before going into break condition. Slave mode: Programming 0 disables the timeout; the last value received a displayed indefinitely.
    Communication Breakdown: Displays “brEAK” after the Master has polled the slave device three times and the response timeout has elapsed. The Snooper and Slave modes go into break condition after no new data is received within the response timeout window. Relays can be programmed to go on, off, or ignore the break condition. The analog outputs can be set up to generate a fixed mA current when a break condition is detected.
    Programmable Constants: Constant P (Adder): -99999 to 999999, default: 0.000; Constant F (Factor): 0.00001 to 999999, default: 1.000
    Math Functions: Addition, difference, absolute difference, average, multiplication, division, max of A or B, min of A or B, draw, weighted average, ratio, concentration. See instruction manual for details.
    Tag & Units: 6-character, independent tag and units for each PV and math channel.
    PV Format: PD6080 default: Decimal format. PD6081 default: FT & IN, 1/8th or 1/16th; decimal format may be selected for bottom display indication. Display Decimal Point: Up to five decimal places or none: d.ddddd, dd.dddd, ddd.ddd, dddd.dd, ddddd.d, or dddddd
    Float Decimal Point: Select the number of decimals to use for the floating point data expected from the slave or master device (this is independent from the display decimal point selection).
    PV & Math Scaling: All PVs and math channels may be scaled to represent the input data in any engineering unit.
       Example: Level transmitter = 999.999 inches; to display in Ft-In-1/16th scale input 2 to display 83 Ft – 4 In – 0/16th.
    Scan Mode: Automatic: 1.0 to 99.9 seconds.
       Manual: Front panel or digital inputs
       Go on alarm: Continues scanning after an alarm is detected
       Stop on alarm: Goes to the alarmed PV and stops scanning; press Scan to resume scanning.

    Relays

    Rating: 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (≈ 50 W) @ 125/250 VAC for inductive loads.
    Noise Suppression: Noise suppression is recommended for each relay contact switching inductive loads.
    Electrical Noise Suppression: A suppressor (snubber) should be connected to each relay contact switching inductive loads to prevent disruption to the microprocessor’s operation. Recommended suppressor value: 0.01 µF/470 Ω, 250 VAC (PDX6901).
    Deadband: 0-100% of span, user programmable
    High or Low Alarm: User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turned off).
    Relay Operation: automatic (non-latching), latching (requires manual acknowledge), sampling (based on time), pump alternation control (2 to 8 relays), Off (disable unused relays and enable interlock feature, manual on/off control mode).
    Relay Reset: User selectable via front panel buttons, digital inputs, or PC.
       1. Automatic reset only (non-latching), when input passes the reset point.
       2. Automatic + manual reset at any time (non-latching).
       3. Manual reset only, at any time (latching).
       4. Manual reset only after alarm condition has cleared (latching).
    Time Delay: 0 to 999.9 seconds, on & off relay time delays. Programmable and independent for each relay.
    Fail-Safe Operation: Programmable and independent for each relay.
    Auto Initialization: When power is applied to the scanner, relays will reflect the state of the input to the scanner.

    Isolated 4-20 mA Transmitter Output

    Output Source: Process Variable 1-16, math channels C1-C4, set points 1-8, or manual control mode
    Scaling Range: 1.000 to 23.000 mA for any display range
    Calibration: Factory calibrated: 4.000 to 20.000 = 4-20 mA output
    Analog Output Programming: 23.000 mA maximum for all parameters: Overrange, under range, max, min, and break
    Communications Break: Programmable mA output when a slave device does not reply within the response timeout
    Accuracy: ±0.1% of span ± 0.004 mA
    Temperature Drift: 0.4 μA/°C max from 0 to 65°C ambient, 0.8 µA/°C max from -40 to 0°C ambient
    Isolated Transmitter Power Supply: Terminals I+ & R: 24 VDC ± 10%. Isolated from the input at >500 V. May be used to power the 4-20 mA output or other devices. All models rated @ 40 mA max.
    External Loop Power Supply: 35 VDC maximum
    Output Loop Resistance:

    Power supplyMinimumMaximum
    24 VDC10Ω700Ω
    35 VDC (external)100Ω1200Ω

    Dual Process Input

    Two Inputs: Two analog inputs, each separately field selectable: 0-20 mA, 4-20 mA; ±10 V (0-5, 1-5, 0-10 V)
    PV Analog Channel ID: Ch-A mA: Assign PV to ID 256 or Ch-A volt: 257; Ch-B mA: Assign PV to ID 258 or Ch-B volt: 259
    Accuracy: ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-100% of calibrated span
    Temperature Drift: 0.005% of calibrated span/±C max from 0 to 65°C ambient, 0.01% of calibrated span/°C max from -40 to 0°C ambient
    Signal Input Conditioning: Linear, square root, programmable exponent, or round horizontal tank volume calculation
    Multi-Point Linearization: 2 to 32 points for PV1 and PV2
    Programmable Exponent: 1.0001 to 2.9999
    Low-Flow Cutoff: 0-999999 (0 disables cutoff function) for PV1 and PV2
    Input Impedance: Voltage ranges: greater than 500 kΩ
    Current ranges: 50 – 100Ω (depending on resettable fuse impedance)
    Input Overload: Current input protected by a resettable fuse, 30 VDC max. Fuse resets automatically after the fault is removed.
    HART Transparency: Analog input will not interfere with existing HART communications on the wired 4-20 mA signal

    Calibration Range: Input RangeMinimum Span Input 1 & Input 2
    10Ω700Ω
    100Ω1200Ω

    Applications

    Signal Input Conditioning

    Non-linear input signals (i.e. weirs & flumes, differential pressure, etc.) can be linearized with the PROVU’s simple to use built-in signal input conditioning, such as: square-root extractor, exponential linearizer, round horizontal tank linearizer, or the PROVU powerful general purpose 32-point linearizer (32 point for for PV1 & PV2 only – all other PVs use two linearization points).


    Weir Flow Calculated Using Exponential Signal Input Conditioning

    Round Horizontal Tank Signal Input Conditioning

    Connections

    • Two isolated supplies available even on 12/24 VDC input power models
    • Removable terminal blocks
    • 2 or 4 relays + isolated 4-20 mA output option
    • Universal 85-265 VAC or 12/24 VDC input power
    • Voltage or current inputs
    • No jumpers needed for V/mA input selection
    • M-Link for adding expansion modules
     

    Mounting Dimensions

    Notes:

    1. Panel cutout required: 1.772″ x 3.622″ (45mm x 92mm)
    2. Panel thickness: 0.040 – 0.250″ (1.0mm – 6.4mm)
    3. Mounting brackets lock in place for easy mounting
    4. Clearance: Allow 6″ (152 mm) behind the panel

    ScanView Software

    ScanView software allows for the programming and monitoring of ProVu, ProtEX-MAX, and Helios series Modbus scanners. Use ScanView to program, monitor, and datalog using a PC. The PVs and math channels may be selected to display on the monitoring screen independently, and the monitoring screen can be customized, so each has a configurable unit and tag. Even the display number colors may be changed. All 16 PVs, math channels, and their units and tags may be logged. The data is logged on the PC and is available for use in common tools like Microsoft Excel. All configuration data can be saved to a file for future use.

    Click here for more information about ScanView

    MeterView® Pro Software

    MeterView Pro VideoMeterView® Pro software is designed for use with ProVu, ProtEX-MAX, or Helios Series meters and allows users to remotely program, monitor, and datalog using a PC. Remote programming allows for all available meter settings to be programmed through an easy, user-friendly interface. The data acquisition feature allows the user to gather readings from a meter at user-selected intervals and generate charts using common tools like Microsoft® Excel. A linearization setup function is also included. With this utility, the user can configure up to 32 linearization points and upload them to the meter. All configuration data can be saved to a file for future use.
    This software is accessible via the onboard USB connection on all Helios large display meters, ProVu panel meters, and ProVu-based ProtEX-MAX explosion-proof meters produced since 6 September 2016 (firmware version 4.0 or higher). In order for meters produced prior to 6 September 2016 (firmware version 3.1 or lower) to establish digital communications with a PC, a serial communications adapter is required. For an RS-232 connection, use a PDA1232 adapter.
    To determine the software version of a meter:

    1. Go to the Diagnostics menu () and press the Enter button.
    2. Press Up arrow button and scroll to Information menu (Info).
    3. Press Enter to access the software number (), version (), and serial number () information. Write down the information as it is displayed. Continue pressing Enter until all the information is displayed.
    4. The meter returns to Run Mode after displaying all the settings.

     

    Monitor and Datalog

    Monitor and Datalog

    Setup

    Setup

    Programming

    Programming

    Relays

    Relays

    Data Sheet:LDS6081 Datasheets

    Instruction Manual:LIM6081_0

    Quick Start Manual

    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm

    Setup, Configuration and Technical Support of our Products are FREE.

    We help to check your faulty Instruments too, fill in the form here

    Free phone and email tech support continues as long as you own the product. Click here for contact information.

    close-link
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm or Email sales@celectric.com.my

    FREE Domestic AND SEA Shipping!

    Most orders RM500/USD120 or more ship SEA for FREE!

    • Delivery within the Southeast Asia only.
    • Hazardous items excluded.
    • Extremely heavy or bulky items excluded.
    • Distributors, Resellers and OEMs excluded.
    • Contact us for shipping charge for orders < RM500/USD120
    close-link
    close-link
    Scroll to Top
    ×