Yokogawa 732 Series Digital Multimeter (Discontinued)

We accept 14 Days Return
Free Delivery within Malysia
See Terms and Conditions for details.

Yokogawa Logo

3.5 digit, 4300 count Mean Value Type Multimeter

Description

Yokogawa 732 Series Digital Multimeter Product Highlights

Specifications – Model 73201/R

Display4300-count digital reading
DC Voltage Accuracy10.75% + 1
AC Voltage Accuracy21% + 5
Additional FunctionsAuto hold, overvoltage and current warning
Features
  • Accuracy 0.5% at DC voltage and 4300 count digital Display
  • Compact size & ideal for carrying
  • Large display for easy viewing
  • Safe design allows measurement in excess of 20A
  • Auto hold function
  • 3 year warranty
Operating Temp and Humidity0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation)
Power SupplyTwo AAA (LR03 or R03) dry cells
Battery LifeApprox. 600 hours (for continuous DC voltage measurement with alkaline cells)
Dimensions74 (W) x 155 (H) x 31 (D) mm
WeightApprox. 240 g (including batteries)
Compliance with StandardsSafety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997)
Standard AccessoriesAAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1
Optional AccessoriesCarrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007)
1 40V – 600V Range 2 4V – 600V Range  

Specifications – Model 73202/R

Display4300-count digital reading
DC Voltage Accuracy10.5% + 1
AC Voltage Accuracy21% + 5
Additional FunctionsAuto hold, overvoltage and current warning
Features
  • Accuracy 0.5% at DC voltage and 4300 count digital Display
  • Compact size & ideal for carrying
  • Large display for easy viewing
  • Safe design allows measurement in excess of 20A
  • Auto hold function
  • 3 year warranty
Operating Temp and Humidity0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation)
Power SupplyTwo AAA (LR03 or R03) dry cells
Battery LifeApprox. 600 hours (for continuous DC voltage measurement with alkaline cells)
Dimensions74 (W) x 155 (H) x 31 (D) mm
WeightApprox. 240 g (including batteries)
Compliance with StandardsSafety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997)
Standard AccessoriesAAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1
Optional AccessoriesCarrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007)
1 40V – 600V Range 2 4V – 600V Range  

Specifications – Model 73203/R

Display4300-count digital reading
DC Voltage Accuracy10.5% + 1
AC Voltage Accuracy20.75% + 1
Additional FunctionsAuto hold, overvoltage and current warning
Features
  • Accuracy 0.5% at DC voltage and 4300 count digital Display
  • Compact size & ideal for carrying
  • Large display for easy viewing
  • Safe design allows measurement in excess of 20A
  • Auto hold function
  • 3 year warranty
Operating Temp and Humidity0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation)
Power SupplyTwo AAA (LR03 or R03) dry cells
Battery LifeApprox. 600 hours (for continuous DC voltage measurement with alkaline cells)
Dimensions74 (W) x 155 (H) x 31 (D) mm
WeightApprox. 240 g (including batteries)
Compliance with StandardsSafety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997)
Standard AccessoriesAAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1
Optional AccessoriesCarrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007)
1 40V – 600V Range 2 4V – 600V Range  

Specifications – Model 73204/R

Display4300-count digital reading
DC Voltage Accuracy10.3% + 1
AC Voltage Accuracy20.75% + 1
Additional FunctionsAuto hold, overvoltage and current warning
Features
  • Accuracy 0.5% at DC voltage and 4300 count digital Display
  • Compact size & ideal for carrying
  • Large display for easy viewing
  • Safe design allows measurement in excess of 20A
  • Auto hold function
  • 3 year warranty
Operating Temp and Humidity0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation)
Power SupplyTwo AAA (LR03 or R03) dry cells
Battery LifeApprox. 600 hours (for continuous DC voltage measurement with alkaline cells)
Dimensions74 (W) x 155 (H) x 31 (D) mm
WeightApprox. 240 g (including batteries)
Compliance with StandardsSafety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997)
Standard AccessoriesAAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1
Optional AccessoriesCarrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007)
1 40V – 600V Range 2 4V – 600V Range